To version 1.16
edited by jadomatis
on 2025/10/03 11:05
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,15 +3,19 @@
3 3  
4 4  = Side-by-Side Overview =
5 5  
6 -|= |= |= |=
7 -|= | | |
8 -|= | | |
9 -|= | | |
10 -|= | | |
11 -|= | | |
12 -|= | | |
13 -|= | | |
14 -|= | | |
15 -|= | | |
6 +|=Area|=Multi-Light|=Multi-Light PLUS|=Why it matters
7 +|=Purpose and form factor|Compact bench-top workstation for everyday marking|Larger Class 1 workstation for bigger parts and extended setups|Choose PLUS variant if you routinely need more room or more complex fixturing
8 +|=Marking field|110 x 110 mm (other lenses optional)|100 x 100 mm (other lenses optional)|Field size is set by the objective; both systems can swap lenses
9 +|=Work chamber/capacity|Max part size - 420 x 300 x 240 mm
10 +Protective cabin - 603 x 505 x 837|(((
11 +Max part size - 881 x 340 x 240 mm
12 +Protective cabin - 1008 x 700 x 880 mm
13 +)))|PLUS variant gives more clearance for tall/long parts, larger fixtures, or rotary setups
14 +|=Axes (built-in)|Automatic Z-axis focusing|Automatic Z-axis focusing|Focusing is equally straightforward on both
15 +|=Safety concept|Class 1 operation with interlocked door and laser protection glass; E-Stop; Status LEDs/acknowledge|Class 1 operation with interlocked door and laser protection glass; E-Stop; Status LEDs/acknowledge|Operating discipline and checks are the same across both machines
16 +|=Software|Either EZCAD (default solution) or AnyMarker Designer (alternative solution)|Either EZCAD (default solution) or AnyMarker Designer (alternative solution)|Software usage remain the same for both so by using it with one machine you will already know how to operate it for the other
17 +|=Options|Objectives, fixtures, rotary axis, extraction units|Same options (sized to cabin)|PLUS's roomier cabin makes fixturing/rotary integration easier