Both Multi-Light and Multi-Light PLUS are enclosed Class 1 laser marking workstations built around a Class 4 fiber laser and operated with either EZCAD or AnyMarker Designer software. They share the same core workflow (design > parameters > focus > pilot laser/camera > run), but they differ in capacity, ergonomics, and configuration flexibility.
Side-by-Side Overview
| Area | Multi-Light | Multi-Light PLUS | Why it matters |
|---|---|---|---|
| Purpose and form factor | Compact bench-top workstation for everyday marking | Larger Class 1 workstation for bigger parts and extended setups | Choose PLUS variant if you routinely need more room or more complex fixturing |
| Marking field | 110 x 110 mm (other lenses optional) | 100 x 100 mm (other lenses optional) | Field size is set by the objective; both systems can swap lenses |
| Work chamber/capacity | Max part size - 420 x 300 x 240 mm Protective cabin - 603 x 505 x 837 | Max part size - 881 x 340 x 240 mm | PLUS variant gives more clearance for tall/long parts, larger fixtures, or rotary setups |
| Axes (built-in) | Automatic Z-axis focusing | Automatic Z-axis focusing | Focusing is equally straightforward on both |
| Safety concept | Class 1 operation with interlocked door and laser protection glass; E-Stop; Status LEDs/acknowledge | Class 1 operation with interlocked door and laser protection glass; E-Stop; Status LEDs/acknowledge | |
| Software | Either EZCAD (default solution) or AnyMarker Designer (alternative solution) | Either EZCAD (default solution) or AnyMarker Designer (alternative solution) | |
| Options | Objectives, fixtures, rotary axis, extraction units | Same options (sized to cabin) | |
| Cooling and airflow | Forced-air | Forced-air | |
| Environmental | +15C to +35C, <90% relative humidity (non-condensing); extraction required for fumes/aerosols/dust | +15C to +35C, <90% relative humidity (non-condensing); extraction required for fumes/aerosols/dust |