Wiki source code of Operation (Start, Run, Shutdown)
Show last authors
| author | version | line-number | content |
|---|---|---|---|
| 1 | This article summarizes the normal operating sequence for the Multi-Light workstation: switching on, running a marking job, and switching off. Only trained personnel may operate the system. Observe all safety notes before use. | ||
| 2 | |||
| 3 | |||
| 4 | = Before You Start = | ||
| 5 | |||
| 6 | * Ambient conditions within specifications; system acclimatized if there were temperature changes. | ||
| 7 | * Machine upright; transport locks removed; airflow at the 19" drawers unobstructed; filter mats clean. | ||
| 8 | * Laser protection window intact; protective housing and door interlocks OK. | ||
| 9 | * Fume/dust extraction ready. | ||
| 10 | |||
| 11 | |||
| 12 | |||
| 13 | = Switch On = | ||
| 14 | |||
| 15 | 1. Verify mains voltage/frequency and cable conditions; mains switch is OFF. | ||
| 16 | 1. Connect the machine, then set the main switch to ON to power electronics. | ||
| 17 | 1. Start the control PC and launch the supplied marking software (we recommend AnyMarker Designer). | ||
| 18 | 1. Confirm the controller is detected and ready (no active fault). | ||
| 19 | **Note**: If a fault is present, movements/functions are inhibited. Clear the cause before proceeding. | ||
| 20 | |||
| 21 | |||
| 22 | |||
| 23 | = Prepare The Job = | ||
| 24 | |||
| 25 | * Place the workpiece; close the door. | ||
| 26 | * Use the pilot laser to display the marking field/contours. | ||
| 27 | * Adjust Z-axis to focus on the surface; best focus is a prerequisite for durable, legible marks. | ||
| 28 | * Shift the workpiece until the correct marking position is reached. | ||
| 29 | |||
| 30 | |||
| 31 | |||
| 32 | = Run The Marking = | ||
| 33 | |||
| 34 | * Load the approved parameter set (power/speed/frequency/fill). | ||
| 35 | * Ensure extraction is running; start the job with the door closed (interlocks engaged). | ||
| 36 | * Monitor status LEDs and messages. Do not leave the machine unattended. | ||
| 37 | * On completion the job ends and the system returns to the ready state. | ||
| 38 | |||
| 39 | |||
| 40 | |||
| 41 | = Quality Check And Adjust = | ||
| 42 | |||
| 43 | * Inspect legibility/contrast; if needed, adjust parameters or Z-focus and repeat a short test. | ||
| 44 | * Typical corrections: increase speed to shorten cycle time, increase power for weak marks, increase hatch spacing if fill is too dense; choose a plotter font if required. | ||
| 45 | |||
| 46 | |||
| 47 | |||
| 48 | = Shutdown = | ||
| 49 | |||
| 50 | 1. Close the software on the PC. | ||
| 51 | 1. Switch the laser system OFF via main switch. | ||
| 52 | 1. Leave the work area clean; never leave the system powered when unattended. | ||
| 53 | |||
| 54 | |||
| 55 | |||
| 56 | = If Something Doesn't Work = | ||
| 57 | |||
| 58 | * Green LED off > system waits for acknowledgement > press blue acknowledge button. | ||
| 59 | * Yellow LED off > door not fully closed > check door closure. | ||
| 60 | * Red LED off with no marking > E-Stop or door open > reset E-Stop, check door. | ||
| 61 | * Mark too weak > verify Z position/focus; increase power/speed; re-focus Z-axis. | ||
| 62 | * (% class="box infomessage" %) | ||
| 63 | ((( | ||
| 64 | Mark too slow > increase speed; increase power; reduce hatch density; use plotter font. | ||
| 65 | For faults that can't be rectified immediately: switch off and contact Schilling Service. Maintenance and repairs should only be performed by Schilling or authorized personnel. | ||