... ... @@ -59,8 +59,5 @@
59 59  * Yellow LED off > door not fully closed > check door closure.
60 60  * Red LED off with no marking > E-Stop or door open > reset E-Stop, check door.
61 61  * Mark too weak > verify Z position/focus; increase power/speed; re-focus Z-axis.
62 -* (% class="box infomessage" %)
63 -(((
64 -Mark too slow > increase speed; increase power; reduce hatch density; use plotter font.
65 -For faults that can't be rectified immediately: switch off and contact Schilling Service. Maintenance and repairs should only be performed by Schilling or authorized personnel.
66 -)))
62 +* Mark too slow > increase speed; increase power; reduce hatch density; use plotter font.
63 +**Note**: For faults that can't be rectified immediately: switch off and contact Schilling Service. Maintenance and repairs should only be performed by Schilling or authorized personnel.