Last modified by jadomatis on 2025/10/06 07:17

From version 1.22
edited by jadomatis
on 2025/09/30 09:40
Change comment: There is no comment for this version
To version 1.23
edited by jadomatis
on 2025/09/30 09:41
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -59,4 +59,5 @@
59 59  * Yellow LED off > door not fully closed > check door closure.
60 60  * Red LED off with no marking > E-Stop or door open > reset E-Stop, check door.
61 61  * Mark too weak > verify Z position/focus; increase power/speed; re-focus Z-axis.
62 -* Mark too slow > 
62 +* Mark too slow > increase speed; increase power; reduce hatch density; use plotter font.
63 +For faults that can't be rect