Changes for page Operation (Start, Run, Shutdown)
Last modified by jadomatis on 2025/10/06 07:17
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -49,4 +49,15 @@ 49 49 50 50 1. Close the software on the PC. 51 51 1. Switch the laser system OFF via main switch. 52 -1. Leave the work area clean; never leave the system powe 52 +1. Leave the work area clean; never leave the system powered when unattended. 53 + 54 + 55 + 56 += If Something Doesn't Work = 57 + 58 +* Green LED off > system waits for acknowledgement > press blue acknowledge button. 59 +* Yellow LED off > door not fully closed > check door closure. 60 +* Red LED off with no marking > E-Stop or door open > reset E-Stop, check door. 61 +* Mark too weak > verify Z position/focus; increase power/speed; re-focus Z-axis. 62 +* Mark too slow > increase speed; increase power; reduce hatch density; use plotter font. 63 +**Note**: For faults that can't be rectified immediately: switch off and contact Schilling Service. Maintenance and repairs should only be performed by Schilling or authorized personnel.