Summary

Details

Page properties
Content
... ... @@ -49,4 +49,15 @@
49 49  
50 50  1. Close the software on the PC.
51 51  1. Switch the laser system OFF via main switch.
52 -1. Leave the work area clean; never leave the system powe
52 +1. Leave the work area clean; never leave the system powered when unattended.
53 +
54 +
55 +
56 += If Something Doesn't Work =
57 +
58 +* Green LED off > system waits for acknowledgement > press blue acknowledge button.
59 +* Yellow LED off > door not fully closed > check door closure.
60 +* Red LED off with no marking > E-Stop or door open > reset E-Stop, check door.
61 +* Mark too weak > verify Z position/focus; increase power/speed; re-focus Z-axis.
62 +* Mark too slow > increase speed; increase power; reduce hatch density; use plotter font.
63 +For faults that can't be rectified immediately: switch off and contact Schilling Service. Maintenance and repairs should only be perfoirn