Caution: Before any maintenance, ensure the system is powered off and de-energized. Follow all laser and electrical safety rules. Do not use flammable or explosive cleaners. No flammable liquids may be present in the work chamber.
Responsibilities and Original Parts
- Maintenance and repairs should be performed by Schilling Marking Systems or other authorized personnel.
- Use original spare parts and consumables. Non-original parts can impair safety and void conformity.
Daily Visual Check
- Protective door and interlocks: no damage; door closes securely; interlocks engages.
- Laser protection window: free of cracks/scratches. If damaged, stop operation and replace.
- Seals and cladding: present, intact, firmly fastened. Do not remove or bypass safety devices.
Airflow, Filters, and Work Environment
- Keep vents and cooling inlets unobstructed (incl. the front 19" drawer area). Heat buildup shortens component life.
- Maintain a clean work area to minimize dust ingress.
- Operate a proper fume/dust extraction unit whenever processing materials that produce gases, vapors, aerosols, or dust. Extraction protects personnel and keeps optics cleaner for longer.
Note: Check the filter mat regularly and replace when soiled to maintain proper cooling airflow.
Cleaning Optical Components
- Use only approved lens wipes/fluids; never use tools or abrasive cloths.
- Remove loose dust with a hand air bulb (no compressed air - risk of oil/water).
- Apply minimal cleaning fluid; wipe in small circular motions from center to edge with light pressure. If