Wiki source code of Maintenance

Version 1.9 by jadomatis on 2025/09/30 10:15

Hide last authors
jadomatis 1.1 1 (% class="box warningmessage" %)
2 (((
jadomatis 1.2 3 **Caution: **Before any maintenance, ensure the system is powered off and de-energized. Follow all laser and electrical safety rules. Do not use flammable or explosive cleaners. No flammable liquids may be present in the work chamber.
jadomatis 1.1 4 )))
jadomatis 1.2 5
6 = Responsibilities and Original Parts =
7
jadomatis 1.3 8 * Maintenance and repairs should be performed by Schilling Marking Systems or other authorized personnel.
jadomatis 1.4 9 * Use original spare parts and consumables. Non-original parts can impair safety and void conformity.
10
11
12
jadomatis 1.5 13 = Daily Visual Check =
14
15 * Protective door and interlocks: no damage; door closes securely; interlocks engages.
jadomatis 1.6 16 * Laser protection window: free of cracks/scratches. If damaged, stop operation and replace.
17 * Seals and cladding: present, intact, firmly fastened. Do not remove or bypass safety devices.
18
19
20
jadomatis 1.7 21 = Airflow, Filters, and Work Environment =
22
jadomatis 1.8 23 * Keep vents and cooling inlets unobstructed (incl. the front 19" drawer area). Heat buildup shortens component life.
24 * Maintain a clean work area to minimize dust ingress.
25 * Operate a proper fume/dust extraction unit whenever processing materials that produce gases, vapors, aerosols, or dust. Extraction protects personnel and keeps optics cleaner for longer.
26 **Note**: Check the filter mat regularly and replace when soiled to maintain proper cooling airflow.
27
28
29
30 = Cleaning Optical Components =
31
32 * Use only approved lens wipes/fluids; never use tools or abrasive cloths.
jadomatis 1.9 33 * Remove loose dust with a hand air bulb (no compressed air - risk of oil/water).
34 * Apply minimal cleaning fluid; wipe in small circular motions from center to edge with light pressure. If