Caution: Before any maintenance, ensure the system is powered off and de-energized. Follow all laser and electrical safety rules. Do not use flammable or explosive cleaners. No flammable liquids may be present in the work chamber.

Responsibilities and Original Parts

  • Maintenance and repairs should be performed by Schilling Marking Systems or other authorized personnel.
  • Use original spare parts and consumables. Non-original parts can impair safety and void conformity.

Daily Visual Check

  • Protective door and interlocks: no damage; door closes securely; interlocks engages.
  • Laser protection window: free of cracks/scratches. If damaged, stop operation and replace.
  • Seals and cladding: present, intact, firmly fastened. Do not remove or bypass safety devices.

Airflow, Filters, and Work Environment

  • Keep vents and cooling inlets unobstructed (incl. the front 19" drawer area). Heat buildup shortens component life.
  • Maintain a clean work area to minimize dust ingress.
  • Operate a proper fume/dust extraction unit whenever processing materials that produce gases, vapors, aerosols, or dust. Extraction protects personnel and keeps optics cleaner for longer.
    Note: Check the filter mat regularly and replace when soiled to maintain proper cooling airflow.

Cleaning Optical Components

  • Use only approved lens wipes/fluids; never use tools or abrasive cloths.
  • Remove loose dust