Changes for page Maintenance
Last modified by jadomatis on 2025/12/17 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -31,4 +31,23 @@ 31 31 32 32 * Use only approved lens wipes/fluids; never use tools or abrasive cloths. 33 33 * Remove loose dust with a hand air bulb (no compressed air - risk of oil/water). 34 -* Apply minimal cleaning fluid; wipe in small circular motions from center to edge with light pressure. If 34 +* Apply minimal cleaning fluid; wipe in small circular motions from center to edge with light pressure. 35 +* If in doubt, stop and consult service - scratches on optics are not repairable. 36 + 37 + 38 + 39 += Avoiding Faults - Typical Causes and Remedies = 40 + 41 +* Weak marking: Re-focus the Z-axis; verify lens is clean; increase power or reduce speed as needed. 42 +* Excessive cycle time: Increase speed; optimize power/fill; use more efficient fonts/hatching where appropriate. 43 +* Thermal alarms/instability: Check airflow, clean vents, replace filter mat, verify room temperature. 44 +* Fumes/deposits in chamber: Increase extraction rate, clean chamber surfaces, review parameters to reduce ablation by-products. 45 + 46 + 47 + 48 += Suggested Maintenance Intervals = 49 + 50 +(% class="box infomessage" %) 51 +((( 52 +Actual intervals depend on environment, duty cycle, and materials. Increase frequency for dusty or high 53 +)))