Changes for page Maintenance

Last modified by jadomatis on 2025/12/17 11:03

From version 1.8
edited by jadomatis
on 2025/09/30 10:14
Change comment: There is no comment for this version
To version 1.12
edited by jadomatis
on 2025/09/30 10:27
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -30,4 +30,26 @@
30 30  = Cleaning Optical Components =
31 31  
32 32  * Use only approved lens wipes/fluids; never use tools or abrasive cloths.
33 -* Remove loose dust
33 +* Remove loose dust with a hand air bulb (no compressed air - risk of oil/water).
34 +* Apply minimal cleaning fluid; wipe in small circular motions from center to edge with light pressure.
35 +* If in doubt, stop and consult service - scratches on optics are not repairable.
36 +
37 +
38 +
39 += Avoiding Faults - Typical Causes and Remedies =
40 +
41 +* Weak marking: Re-focus the Z-axis; verify lens is clean; increase power or reduce speed as needed.
42 +* Excessive cycle time: Increase speed; optimize power/fill; use more efficient fonts/hatching where appropriate.
43 +* Thermal alarms/instability: Check airflow, clean vents, replace filter mat, verify room temperature.
44 +* Fumes/deposits in chamber: Increase extraction rate, clean chamber surfaces, review parameters to reduce ablation by-products.
45 +
46 +
47 +
48 += Suggested Maintenance Intervals =
49 +
50 +(% class="box infomessage" %)
51 +(((
52 +Actual intervals depend on environment, duty cycle, and materials. Increase frequency for dusty or high-throughput use.
53 +)))
54 +
55 +* Daily: Visual safety check (door/