Changes for page Maintenance

Last modified by jadomatis on 2025/12/17 11:03

From version 1.4
edited by jadomatis
on 2025/09/30 10:04
Change comment: There is no comment for this version
To version 1.9
edited by jadomatis
on 2025/09/30 10:15
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -10,4 +10,25 @@
10 10  
11 11  
12 12  
13 -
13 += Daily Visual Check =
14 +
15 +* Protective door and interlocks: no damage; door closes securely; interlocks engages.
16 +* Laser protection window: free of cracks/scratches. If damaged, stop operation and replace.
17 +* Seals and cladding: present, intact, firmly fastened. Do not remove or bypass safety devices.
18 +
19 +
20 +
21 += Airflow, Filters, and Work Environment =
22 +
23 +* Keep vents and cooling inlets unobstructed (incl. the front 19" drawer area). Heat buildup shortens component life.
24 +* Maintain a clean work area to minimize dust ingress.
25 +* Operate a proper fume/dust extraction unit whenever processing materials that produce gases, vapors, aerosols, or dust. Extraction protects personnel and keeps optics cleaner for longer.
26 +**Note**: Check the filter mat regularly and replace when soiled to maintain proper cooling airflow.
27 +
28 +
29 +
30 += Cleaning Optical Components =
31 +
32 +* Use only approved lens wipes/fluids; never use tools or abrasive cloths.
33 +* Remove loose dust with a hand air bulb (no compressed air - risk of oil/water).
34 +* Apply minimal cleaning fluid; wipe in small circular motions from center to edge with light pressure. If