... ... @@ -5,4 +5,29 @@
5 5  
6 6  = Responsibilities and Original Parts =
7 7  
8 -* Maintenan
8 +* Maintenance and repairs should be performed by Schilling Marking Systems or other authorized personnel.
9 +* Use original spare parts and consumables. Non-original parts can impair safety and void conformity.
10 +
11 +
12 +
13 += Daily Visual Check =
14 +
15 +* Protective door and interlocks: no damage; door closes securely; interlocks engages.
16 +* Laser protection window: free of cracks/scratches. If damaged, stop operation and replace.
17 +* Seals and cladding: present, intact, firmly fastened. Do not remove or bypass safety devices.
18 +
19 +
20 +
21 += Airflow, Filters, and Work Environment =
22 +
23 +* Keep vents and cooling inlets unobstructed (incl. the front 19" drawer area). Heat buildup shortens component life.
24 +* Maintain a clean work area to minimize dust ingress.
25 +* Operate a proper fume/dust extraction unit whenever processing materials that produce gases, vapors, aerosols, or dust. Extraction protects personnel and keeps optics cleaner for longer.
26 +**Note**: Check the filter mat regularly and replace when soiled to maintain proper cooling airflow.
27 +
28 +
29 +
30 += Cleaning Optical Components =
31 +
32 +* Use only approved lens wipes/fluids; never use tools or abrasive cloths.
33 +* Remove loose dust