... ... @@ -30,29 +30,4 @@
30 30  = Cleaning Optical Components =
31 31  
32 32  * Use only approved lens wipes/fluids; never use tools or abrasive cloths.
33 -* Remove loose dust with a hand air bulb (no compressed air - risk of oil/water).
34 -* Apply minimal cleaning fluid; wipe in small circular motions from center to edge with light pressure.
35 -* If in doubt, stop and consult service - scratches on optics are not repairable.
36 -
37 -
38 -
39 -= Avoiding Faults - Typical Causes and Remedies =
40 -
41 -* Weak marking: Re-focus the Z-axis; verify lens is clean; increase power or reduce speed as needed.
42 -* Excessive cycle time: Increase speed; optimize power/fill; use more efficient fonts/hatching where appropriate.
43 -* Thermal alarms/instability: Check airflow, clean vents, replace filter mat, verify room temperature.
44 -* Fumes/deposits in chamber: Increase extraction rate, clean chamber surfaces, review parameters to reduce ablation by-products.
45 -
46 -
47 -
48 -= Suggested Maintenance Intervals =
49 -
50 -(% class="box infomessage" %)
51 -(((
52 -Actual intervals depend on environment, duty cycle, and materials. Increase frequency for dusty or high-throughput use.
53 -)))
54 -
55 -* Daily: Visual safety check (door/interlocks, window, seals), clear vents, verify extraction.
56 -* Weekly: Inspect and clean chamber surfaces; quick optics inspection; check filter mat condition.
57 -* Monthly: Replace filter mat if soiled; inspect cabling, fans, and emergency-stop function.
58 -* Quarterly/Semi-annual: Full optics inspection/clean, verify
33 +* Remove loose dust