... ... @@ -49,5 +49,10 @@
49 49  
50 50  (% class="box infomessage" %)
51 51  (((
52 -Actual intervals depend on environment, duty cycle, and materials. Increase frequency for dusty or high
52 +Actual intervals depend on environment, duty cycle, and materials. Increase frequency for dusty or high-throughput use.
53 53  )))
54 +
55 +* Daily: Visual safety check (door/interlocks, window, seals), clear vents, verify extraction.
56 +* Weekly: Inspect and clean chamber surfaces; quick optics inspection; check filter mat condition.
57 +* Monthly: Replace filter mat if soiled; inspect cabling, fans, and emergency-stop function.
58 +* Quarterly/Semi-annual: Full optics inspection/clean, verify