... ... @@ -6,43 +6,4 @@
6 6  = Responsibilities and Original Parts =
7 7  
8 8  * Maintenance and repairs should be performed by Schilling Marking Systems or other authorized personnel.
9 -* Use original spare parts and consumables. Non-original parts can impair safety and void conformity.
10 -
11 -
12 -
13 -= Daily Visual Check =
14 -
15 -* Protective door and interlocks: no damage; door closes securely; interlocks engages.
16 -* Laser protection window: free of cracks/scratches. If damaged, stop operation and replace.
17 -* Seals and cladding: present, intact, firmly fastened. Do not remove or bypass safety devices.
18 -
19 -
20 -
21 -= Airflow, Filters, and Work Environment =
22 -
23 -* Keep vents and cooling inlets unobstructed (incl. the front 19" drawer area). Heat buildup shortens component life.
24 -* Maintain a clean work area to minimize dust ingress.
25 -* Operate a proper fume/dust extraction unit whenever processing materials that produce gases, vapors, aerosols, or dust. Extraction protects personnel and keeps optics cleaner for longer.
26 -**Note**: Check the filter mat regularly and replace when soiled to maintain proper cooling airflow.
27 -
28 -
29 -
30 -= Cleaning Optical Components =
31 -
32 -* Use only approved lens wipes/fluids; never use tools or abrasive cloths.
33 -* Remove loose dust with a hand air bulb (no compressed air - risk of oil/water).
34 -* Apply minimal cleaning fluid; wipe in small circular motions from center to edge with light pressure.
35 -* If in doubt, stop and consult service - scratches on optics are not repairable.
36 -
37 -
38 -
39 -= Avoiding Faults - Typical Causes and Remedies =
40 -
41 -* Weak marking: Re-focus the Z-axis; verify lens is clean; increase power or reduce speed as needed.
42 -* Excessive cycle time: Increase speed; optimize power/fill; use more efficient fonts/hatching where appropriate.
43 -* Thermal alarms/instability: Check airflow, clean vents, replace filter mat, verify room temperature.
44 -* Fumes/deposits in chamber: Increase extraction rate, clean chamber surfaces, review parameters to reduce ablation by-products.
45 -
46 -
47 -
48 -= Suggested Maintenance Intervals =
9 +* Use original spare parts and consumables. Non-original parts can impair safety and v