| 1 | (% class="box warningmessage" %) | ||
| 2 | ((( | ||
| 3 | **Caution: **Before any maintenance, ensure the system is **powered off and de-energized**. Follow all laser and electrical safety rules. **Do not use flammable** **or explosive cleaners**. No flammable liquids may be present in the work chamber. | ||
| 4 | ))) | ||
| 5 | |||
| 6 | = Responsibilities and Original Parts = | ||
| 7 | |||
| 8 | * Maintenance and repairs should be performed by **Schilling Marking Systems** or **other authorized personnel**. | ||
| 9 | * Use **original spare parts and consumables**. Non-original parts can impair safety and void conformity. | ||
| 10 | |||
| 11 | |||
| 12 | |||
| 13 | = Daily Visual Check = | ||
| 14 | |||
| 15 | * **Protective door and interlocks**: no damage; door closes securely; interlocks engages. | ||
| 16 | * **Laser protection window**: free of cracks/scratches. If damaged, stop operation and replace. | ||
| 17 | * **Seals and cladding**: present, intact, firmly fastened. Do not remove or bypass safety devices. | ||
| 18 | |||
| 19 | |||
| 20 | |||
| 21 | = Airflow, Filters, and Work Environment = | ||
| 22 | |||
| 23 | * Keep **vents and cooling inlets** unobstructed (incl. the front 19" drawer area). Heat buildup shortens component life. | ||
| 24 | * Maintain a** clean work area **to minimize dust ingress. | ||
| 25 | * Operate a **proper fume/dust extraction unit** whenever processing materials that produce gases, vapors, aerosols, or dust. Extraction protects personnel and keeps optics cleaner for longer. | ||
| 26 | **Note**: Check the filter mat regularly and **replace when soiled** to maintain proper cooling airflow. | ||
| 27 | |||
| 28 | |||
| 29 | |||
| 30 | = Cleaning Optical Components = | ||
| 31 | |||
| 32 | * Use **only approved lens wipes/fluids**; never use tools or abrasive cloths. | ||
| 33 | * Remove loose dust with a **hand air bulb** (no compressed air - risk of oil/water). | ||
| 34 | * Apply minimal cleaning fluid; wipe in **small circular motions from center to edge** with light pressure. | ||
| 35 | * If in doubt, stop and consult service - scratches on optics are** not repairable**. | ||
| 36 | |||
| 37 | |||
| 38 | |||
| 39 | = Avoiding Faults - Typical Causes and Remedies = | ||
| 40 | |||
| 41 | * **Weak marking**: Re-focus the **Z-axis**; verify lens is clean; increase power or reduce speed as needed. | ||
| 42 | * **Excessive cycle time**: Increase speed; optimize power/fill; use more efficient fonts/hatching where appropriate. | ||
| 43 | * **Thermal alarms/instability**: Check airflow, clean vents, **replace filter mat**, verify room temperature. | ||
| 44 | * **Fumes/deposits in chamber**: Increase extraction rate, clean chamber surfaces, review parameters to reduce ablation by-products. | ||
| 45 | |||
| 46 | |||
| 47 | |||
| 48 | = Suggested Maintenance Intervals = | ||
| 49 | |||
| 50 | (% class="box infomessage" %) | ||
| 51 | ((( | ||
| 52 | Actual intervals depend on environment, duty cycle, and materials. Increase frequency for dusty or high-throughput use. | ||
| 53 | ))) | ||
| 54 | |||
| 55 | * **Daily**: Visual safety check (door/interlocks, window, seals), clear vents, verify extraction. | ||
| 56 | * **Weekly**: Inspect and clean chamber surfaces; quick optics inspection; check filter mat condition. | ||
| 57 | * **Monthly**: Replace filter mat if soiled; inspect cabling, fans, and emergency-stop function. | ||
| 58 | * **Quarterly/Semi-annual**: Full optics inspection/clean, verify door alignment and interlock function, review parameter presets and backups. | ||
| 59 | * **As needed**: Replace worn accessories/consumables; update software and controller firmware per vendor guidance. | ||
| 60 | |||
| 61 | |||
| 62 | |||
| 63 | = After Maintenance - Return to Service = | ||
| 64 | |||
| 65 | 1. Confirm all covers, seals, and safety devices are **reinstalled and secure**. | ||
| 66 | 1. Power up the system and check **status indicators/notifications**. | ||
| 67 | 1. Verify **extraction **is operating. | ||
| 68 | 1. Perform a **short test mark** on sample material to confirm quality and focus. |