Wiki source code of Commissioning and First Start-Up
Hide last authors
| author | version | line-number | content |
|---|---|---|---|
| |
1.1 | 1 | = Preconditions (Before Switching On) = |
| 2 | |||
| 3 | Confirm the following before applying power: | ||
| 4 | |||
| |
1.3 | 5 | * Electrical installation is correct; mains voltage and frequency match the rating place. Main switch is OFF. |
| |
1.4 | 6 | * Protective housing and door interlocks are intact; laser viewing window shows now damage. |
| 7 | * Optics are clean; remove any transport/lens cover only now. Avoid touching optics with bare hands. | ||
| |
1.5 | 8 | * Ambient conditions: +15C to +35C. RH <90% non condensing; system acclimatized if temperature changed during transport. |
| |
1.6 | 9 | * Airflow at 19" drawers is unobstructed; filter mats are clean to prevent heat build-up. |
| 10 | * Operator is familiar with laser safety requirements; responsibilities are defined. | ||
| |
1.7 | 11 | Note: The Multi-Light contains a Class 4 source operated as Class 1 in the closed cabin. Never bypass safety devices. |
| 12 | |||
| 13 | |||
| 14 | |||
| |
1.8 | 15 | = Electrical Start-Up = |
| 16 | |||
| 17 | 1. Connect the system to the specified mains supply. Ensure extraction is running. | ||
| |
1.10 | 18 | 1. Set the mains switch to ON. Internal electronics initialize; status indicators light as described on the operator panel. |
| 19 | 1. Power on the control PC (or workstation) and peripherals needed for operation. | ||
| 20 | |||
| 21 | |||
| 22 | |||
| |
1.11 | 23 | = Software and Device Connection = |
| 24 | |||
| |
1.12 | 25 | 1. Launch the AnyMarker Designer software. |
| 26 | 1. Verify communication with the laser controller in the software (device connected, parameters readable). | ||
| 27 | If connection fails, switch OFF, check cabling and restart. | ||
| 28 | |||
| 29 | |||
| 30 | |||
| |
1.13 | 31 | = Initial Checks With Pilot Laser = |
| 32 | |||
| 33 | * Load or create a test layout in AnyMarker Designer. | ||
| |
1.14 | 34 | * Enable the pilot laser to project contours on the workpiece; verify orientation and placement without laser emission. Keep the door closed. |
| 35 | |||
| 36 | |||
| 37 | |||
| |
1.15 | 38 | = Z-Axis Focusing = |
| 39 | |||
| 40 | 1. Place the workpiece/fixture in the work chamber and close the manual lift door. | ||
| |
1.16 | 41 | 1. Use the automatic Z-axis to set focus to the surface (per lens focal distance). Follow the on-screen/readout guidance for focal height. |
| 42 | 1. Confirm best focus by pilot outline sharpness or focus gauge method recommended in the manual. | ||
| 43 | |||
| 44 | |||
| 45 | |||
| |
1.17 | 46 | = Parameter Verification = |
| 47 | |||
| |
1.18 | 48 | * Select a verified marking parameter set (power, speed, frequency, fill). Start with conservative energy to avoid burning or glare. |
| 49 | * Ensure extraction is active to remove gases, vapors, aerosols, and dust during test marking. | ||
| 50 | |||
| 51 | |||
| 52 | |||
| |
1.19 | 53 | = First Test Mark = |
| |
1.20 | 54 | |
| 55 | 1. With the cabin closed and interlocks engaged, execute a short test mark on a sample of the target material. | ||
| |
1.21 | 56 | 1. Observe quality and adjust parameters (e.g., reduce power/increase speed) as needed. Multiple repetitions may be used for depth, but monitor temperature to reduce fire risk. |
| 57 | 1. If unexpected behavior occurs, press STOP/EMERGENCY-STOP, investigate messages in Notifications, and correct the cause before resuming. | ||
| 58 | |||
| 59 | |||
| 60 | |||
| |
1.22 | 61 | = Post-Test Verification = |
| 62 | |||
| 63 | * Inspect the mark; check legibility/contrast. Clean light residue if necessary. | ||
| |
1.23 | 64 | * Re-check filters/airflow after prolonged tests. Excess dust must not accumulate. |
| 65 | * Document the approved parameter set for production. | ||
| 66 | |||
| 67 | |||
| 68 | |||