Version 1.15 by jadomatis on 2025/09/29 13:06

Hide last authors
jadomatis 1.1 1 = Preconditions (Before Switching On) =
2
3 Confirm the following before applying power:
4
jadomatis 1.3 5 * Electrical installation is correct; mains voltage and frequency match the rating place. Main switch is OFF.
jadomatis 1.4 6 * Protective housing and door interlocks are intact; laser viewing window shows now damage.
7 * Optics are clean; remove any transport/lens cover only now. Avoid touching optics with bare hands.
jadomatis 1.5 8 * Ambient conditions: +15C to +35C. RH <90% non condensing; system acclimatized if temperature changed during transport.
jadomatis 1.6 9 * Airflow at 19" drawers is unobstructed; filter mats are clean to prevent heat build-up.
10 * Operator is familiar with laser safety requirements; responsibilities are defined.
jadomatis 1.7 11 Note: The Multi-Light contains a Class 4 source operated as Class 1 in the closed cabin. Never bypass safety devices.
12
13
14
jadomatis 1.8 15 = Electrical Start-Up =
16
17 1. Connect the system to the specified mains supply. Ensure extraction is running.
jadomatis 1.10 18 1. Set the mains switch to ON. Internal electronics initialize; status indicators light as described on the operator panel.
19 1. Power on the control PC (or workstation) and peripherals needed for operation.
20
21
22
jadomatis 1.11 23 = Software and Device Connection =
24
jadomatis 1.12 25 1. Launch the AnyMarker Designer software.
26 1. Verify communication with the laser controller in the software (device connected, parameters readable).
27 If connection fails, switch OFF, check cabling and restart.
28
29
30
jadomatis 1.13 31 = Initial Checks With Pilot Laser =
32
33 * Load or create a test layout in AnyMarker Designer.
jadomatis 1.14 34 * Enable the pilot laser to project contours on the workpiece; verify orientation and placement without laser emission. Keep the door closed.
35
36
37
jadomatis 1.15 38 = Z-Axis Focusing =
39
40 1. Place the workpiece/fixture in the work chamber and close the manual lift door.
41 1. Use the automatic Z-axis to set focus to the surface (per lens focal distance). Follow