Commissioning and First Start-Up

Version 1.5 by jadomatis on 2025/09/29 11:19

Preconditions (Before Switching On)

Confirm the following before applying power:

  • Electrical installation is correct; mains voltage and frequency match the rating place. Main switch is OFF.
  • Protective housing and door interlocks are intact; laser viewing window shows now damage.
  • Optics are clean; remove any transport/lens cover only now. Avoid touching optics with bare hands.
  • Ambient conditions: +15C to +35C. RH <90% non condensing; system acclimatized if temperature changed during transport.
  • Airflow at 19" drawers is unobstructed;